Documentation made available quickly and It is good quality. Thanks.
Tekstowy podgląd strony 8 (kliknij aby zobaczyć)
CONFIDENTIAL
3 Disassembly and Reassembly
This section of the service manual describes the disassembly and reassembly procedures for the CA19JS monitor. WARNING: This monitor contains electrostatically sensitive devices. Use with caution when handling these components.
3-1 Disassembly
Cautions:1. Disconnect the monitor from the power source before disassembly. 2. To remove the Rear Cover, you must use the special opening jig tool.
3-1-1 Before Disassembly
1. Disconnect power cord from the monitor. 2. With a pad beneath it, stand the monitor on its front with the screen facing downward and the base close to you.
4. Push the opening jig in to each groove along the side of the monitor until it makes a �ttak� sound. (2 grooves : Left and right, make sure each snap is disengaged.)
3-1-2 Cabinet Disassembly
1. Remove the Stand from the monitor. (Refer to stand manual) 2. Remove 2 screws on the rear cover.
Figure 3 5. Pull the rear cover up and away from the monitor.
Figure 1 3. Tilt the monitor by lifting at the rear.