Gruba instrukcja - poprostu wszystko co potrzreba - polecam .
Tekstowy podgląd strony 9 (kliknij aby zobaczyć)
Excessive Weight Hazard Use 2 or more people to move and install air conditioner. Failure to do so can result in back or other injury.
4. Remove side curtains. Slide curtains out to their fullest width. From the back side, remove the Phillips-head screws (A) holding the curtains to the cabinet. 5. Remove the slotted hex-head screws (B) holding the top channel. 6. Remove the slotted hex-head screws (C) on the sides of the cabinet. 7. Holding both sides of the cabinet, carefully lift the cabinet off the base. Watch out for the sharp metal fins on the front and rear coils. 8. Wrap the motor, electrical control box, and the compressor terminal box in plastic film to make sure no water or other liquid gets inside. Water or other liquids could damage the insulation and cause serious mechanical problems. 9. Clean and hose out the base, coils, and condensate pans. Clean at least once a year, or more often if the condenser coils and pans collect dirt, sand, leaves, insects, or algae. Also, clean if you detect an odor coming from the air conditioner. Do not use the collected water for drinking purposes. It is not sanitary. 10. Remove plastic film from motor and electrical parts. 11. Replace unit in the cabinet. Reattach top channel and side curtains. Tighten all screws. 12. Reinstall unit in the window. 13. Replace the front panel. 14. Plug in the power cord. NOTE: It is a good idea to wait 24 hours before starting the unit again. This allows time !or all areas to dry thoroughly. The water from rainfall or from normal operation does not harm the components. 9