DIMENSIONS OF COOKING HOB AND WORKTOP
NOTES: If the distance �A� between the wall cabinets is between 600 mm and 680 mm, the height �B� must be a minimum of 520 mm. If the distance �A� between the wall cabinets is greater than the width of the cooktop, the height �B� must be a minimum of 400 mm. In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance. INJECTORS TABLE
Type of gas used NATURAL GAS Type of burner Injector marking 128 94 76 85 65 50 85 65 50 Rated heat capacity Pcs-kW 3.00 1.65 1.00 3.00 1.65 1.00 3.00 1.65 1.00 Rated Reduced heat consumption capacity Pcs-kW 286 l/h 157 l/h 95 l/h 218 g/h 120 g/h 73 g/h 214 g/h 118 g/h 71 g/h 0.60 0.35 0.30 0.60 0.35 0.30 0.60 0.35 0.30
CATEGORY II2H3+
Gas pressure min. 17 rat. 20 max. 25
large medium (Methane) G 20 small LIQUID PETROLEUM large GAS medium (Cylinder) G 30 small LIQUID PETROLEUM large GAS medium (Cylinder) G 31 small
20
28-30
35
25
37
45
Type of gas used G 20 20 mbar G 30 28-30 mbar G 31 37 mbar