...instrukcja serwisowa w pełni czytelna i kompletna. Dziękuję!
Tekstowy podgląd strony 6 (kliknij aby zobaczyć)
DCR-IP5/IP5E/IP7BT/IP7E
SERVICE NOTE
1.
POWER SUPPLY DURING REPAIRS
In this unit, about 10 seconds after power is supplied to the battery terminal using the regulated power supply (8.4V), the power is shut off so that the unit cannot operate. These following two methods are available to prevent this. Take note of which to use during repairs. Method 1. Use the AC power adaptor (AC-L20, AC-VF50). Method 2. Connect the servicing remote commander RM-95 (J-6082-053-B) to the A/V jack, and set the commander switch to the �ADJ� side.
2.
1 2 3 4
TO TAKE OUT A CASSETTE WHEN NOT EJECT (FORCE EJECT)
Refer to 2-2 to remove the cabinet (R) assembly. Disconnect CN2009 (31P, 0.3mm) of VC-263 board. Open the cassette lid. Supply +4.5V from the regulated power supply to the loading motor and unload with a pressing the cassette compartment.