Documentation made available quickly and It is good quality. Thanks.
Tekstowy podgląd strony 4 (kliknij aby zobaczyć)
DPF-3030/3030E/3030-S
ADJUSTMENT
No. ITEM INPUT SETTING OUTPUT SETTING PLAYER SETTING ALIGNMENT POINT ALIGN FOR FIG.
1. With pressing the "PEAK SEARCH" key, turn the power on to enter the test mode. 2. Press the "OPEN/CLOSE" key and then load the test disc on the tray. 3. To close the tray, press the "OPEN/CLOSE" key. Connect an oscilloscope to TP200 RF (PIN 2) VC (PIN 1) Press the "PLAY/PAUSE" key. Confirm that the display is "05". Press the "PLAY/PAUSE" key. Confirm that the display is 03 or 05. Note: Type 4 disc : SONY YEDS-18 Test Disc or equivalent. LPF: Around 47 k�+ 390 pF or so. � 0.5V ± 0.2V (a) VR200 Optimum eye pattern
1
FOCUS OFFSET
TEST DISC TYPE 4
2
LASER CURRENT CHECK
TEST DISC TYPE 4
Connect the DC voltmeter to R202(both ends).
(a) TEST POINT OF LASER CURRENT
R202 (10�) TEST POINT