6. To reassemble, carefully repeat the steps for disassembly in reverse order.
Note:
- Firmly engage the locks on the lockable connector.
<LC panel handling precautions> 1. If burn on appears on the LC panel, leave it for a day with the power off. 2. The LC panel is a high grade glass product. It can easily be damaged by vibration, shocks and twisting.Do not press on the panel surface. This can cause deterioration of the picture and malfunction. 3. Do not touch the terminals of the flexible cable with bare hands. This can cause damage through static electricity. 4. Sticking of the waterdrop to the LC panel surface causes discoloration or stain. Wipe off quickly. (Care) 1. Clean the surface with gauze or other soft cloth soaked in isopropyl alcohol or 3. When cleaning, do not use water, cetones benzene. (acetone, etc.), aromatic compounds 2. Do not wipe the surface with dry gauze, as (xylene, toluene, etc.), or halogens under this can scratch the surface. any circumstances.