Entra Three
ACOUSTIC & ELECTRICAL SPECIFICATIONS: � Nominal Impedance 8 ohms � Max Amp Power 150 watts* � Frequency Response 40Hz � 20,000Hz (±3dB) � Sensitivity 91dB (2.83V @ 1 meter) � Crossover Frequency 2000Hz; 24dB/octave SYSTEM COMPONENTS: � Cabinet � Grille � Low-Frequency Transducer AURAL SWEEP TEST SPECIFICATIONS: � System Aural Sweep Test 6.0V input 40Hz to 20kHz � L.F. Aural Sweep Test 5.0V input 40Hz to 3kHz � H.F. Aural Sweep Test 2.83V input 1kHz to 20kHz PHYSICAL SPECIFICATIONS: � Enclosure dimensions
®
DC Resistance � High-Frequency Transducer
DC Resistance � Crossover Network
ENTRA THREE (not for sale) � Weight 338598-001 Dual 6-1/2" (165mm) WARRANTY: CMMD, magnetically � � Refer to Warranty Statement packed with each product. shielded (338915-001) 8.1 ohms ±10% 3/4" (19mm) CMMD, * The maximum recommended amplifier power rating will magnetically shielded ensure proper system headroom to allow for occasional (336417-001) peaks. We do not recommend sustained operation at these 3.3 ohms ±10% maximum power levels. 338599-001
37-1/2" x 8-1/2" x 12-3/4" (953mm x 216mm x 324mm) 38 lb (17.3kg) each