IOP Data Recording and Display When optical Pick-up and Non-volatile Memory (IC171 of BD (MD)board) are Replaced
The IOP value labeled on the optical pick-up can be recorded in the non-volatile memory. By recording the value, it will eliminate the need to look at the value on the label of the optical pick-up. When replacing the optical pick-up or non-volatile memory (IC171 of BD (MD) board), record the IOP value on the optical pick-up according to the following procedure. Record Precedure: 1. When the power ON, press the ?/1 button while pressing the s button and z (TAPE) button together. 2. Press the lm/TUNING � button or ML/TUNING + button to display �[Service]�, and press the ENTER/YES �R� button. 3. Press the lm/TUNING � button or ML/TUNING + button to display � lop Write�, and press the ENTER/YES �R� button. 4. The display becomes �Ref=@@@.@� (@ is an arbitrary number) and the numbers which can be changed will blink. 5. Input the IOP value written on the optical pick-up. To select the number : Press the lm/TUNING � button or ML/TUNING + button. To select the digit : Press the SYNCHRO REC button and ENTER/START button at the sawe time. Note 1) Note 1 : If a message �Can not SYNC!� or �NO TAPE� appears momentarily, press SYNCRO REC button several times until �CD-MD SYNC?� appears momentarily. When the ENTER/YES �R� button is pressed, the display becomes �Measu=@@@.@� (@ is an arbitrary number). As the adjustment results are recorded for the 6 value. Leave it as it is and press the ENTER/YES �R� button. �Complete!� will be displayed momentarily. The value will be recorded in the non-volatile memory and the display will become �Iop Write�. Press the REPEAT/DOLBY NR/STEREO/MONO button to exit.
6. 7. 8. 9.
Display Precedure: 1. When the power ON, press the ?/1 button while pressing the s button and z (TAPE) button together. 2. Press the lm/TUNING � button or ML/TUNING + button to display �[Service]�, and press the ENTER/YES �R� button. 3. Press the lm/TUNING � button or ML/TUNING + button to display �lop Read�, and press the ENTER/YES �R� button. @@.@ : indicates the Iop value labeled on the pick-up. ##.# : indicates the Iop value after adjustment 5. To end, press MENU/NO �R� button to display �Iop Read�. Then press the REPEAT/DOLBY NR/STEREO/MONO button to display �Standby�.
13
|
|
|
> |
|