[HR-J271MS/J471MS] (1) Connect the frequency counter to the measuring point (D1). (2) Connect the short wire between the short point (D2) and GND. (3) Short the leads of capacitor (D3) once in order to reset the microprocessor of the SYSCON. (4) Adjust the Adjustment part (F) so that the output frequency becomes the specified value (G). [HR-J677MS/J777MS] (1) Connect the frequency counter to the measuring point (D1). (2) Connect the short wire between the short point (D2) and Vcc (5V). (3) Short the leads of capacitor (D3) once in order to reset the microprocessor of the SYSCON. (4) Disconnect the short wire between the short point (D2) and Vcc then connect it again. (5) Adjust the Adjustment part (F) so that the output frequency becomes the specified value (G).