Tekstowy podgląd strony 80 (kliknij aby zobaczyć)
Replacement 1. Insert the appropriate end of the ribbon cable through the slotted opening in the Paper Feed / Carriage Assembly approximately three inches (Figure 4a).
2. Gently maneuver the cable to the right through the 45° slot until positioned as shown in Figure 4b.
3. Pull the cable downward through the slotted opening until the 45° fold is positioned as shown in Figure 4c.
4. Lock the cable beneath the cable edge restraints. The printed side of the ribbon cable should be facing upward. 5. Insert the free end of the cable into the carriage BOARD connector; slide the connector lock to the locked position. Ensure the cable is below the molded cable restraint (Figure 3). 6. Reinstall the carriage shaft into the carriage.