Alignment and Adjustments
4-4 Other Adjustments
4-4-1 Screen Adjustment
1. Warm up the TV for at least 30 minutes. 2. Turn to the Video Mode (No Signal) using a remote-control. 3. Connect an oscilloscope to RK,GK,BK. 4. Adjust the VR (VR501, VR531, VR561) screen so that RK, GK, BK pulse is 20Vp-p each. (Turn the R,G,B VR screen fully counterclockwise in the area of each flyback line.)
4-4-3 Sub-Brightness Adjustment
1. Input a sub-brightness adjustment signal. (TOSHIBA PATTERN) 2. In the stand-by mode, press the remote-control keys in the following sequence : Mute - 1 - 8 - 2 - Power ON 3. Select SBT by pressing the Volume +/- keys. 4. Adjust so that the 7th step on the right side of the screen is not seen (Use the Volume +/keys). 5. Press the Menu key to exit.
4-4-2 White Balance Adjustment
1. Select the �STANDARD� video mode. 2. Input 100% white pattern. 3. In the stand-by mode, press the remote-control keys in the following sequence: Mute � 1 � 8 � 2 � Power ON 4. Warm up the TV for at least 30 minutes. 5. Input a 10-step signal. 6. R-cut off, B-cut off, and G-cut off by pressing the Volume +/- keys. 7. Adjust the low light with viewing the dark side of the screen. 8. Select R-drive, G-drive, and B-drive by pressing the Volume +/- keys. 9. Adjust the high light with viewing the light side of the screen. 10. If necessary, redo adjustments 6~9. 11. Press the Menu key to exit.
4-4-4 High Voltage (31KV) Check
PRECAUTION
1. Input a lion head pattern. 2. Select �STANDARD� video mode. 3. Warm up the TV for at least 10 minutes. 4. Use a 1000:1 probe.
ADJUSTMENT
1. Connect the (+) terminal of the 1000:1 probe to the high voltage distributor and the (-) terminal to GND (located on the deflection board). 2. Adjust VR471 (located on the deflection board) so that the digital meter indicates DC 31V ± 0.1V.