...instrukcja serwisowa w pełni czytelna i kompletna. Dziękuję!
Tekstowy podgląd strony 12 (kliknij aby zobaczyć)
HOW TO USE THE DVC HEAD CLEANING TAPE / LSUQ0003
Please use the cleaning tape as described below. Note: This cleaning tape has a total playback time of 45 minutes. Once used, it is not reusable. 1. Confirm the picture. NG 2. Playback the cleaning tape for 20 seconds. 3. Confirm the picture again. NG 4. Playback the cleaning tape for 20 seconds. 5. Confirm the picture again. NG 6. Playback the cleaning tape for 20 seconds. 7. Confirm the picture again. NG 8. Replace the Cylinder Unit OK The picture will look like this in case of clogged video head. OK
OK
Playback any normal DVC tape for 20 minutes or over.
OK
Fig. 7
HOW TO REPLACE THE LAMP (VLLW0023) OF ENHANCEMENT LIGHT UNIT (MODEL: D)
DANGER:
To prevent possible burn hazard, disconnect this unit and allow lamp to cool before replacing. Replace only with VLLW0023 lamp, to reduce the risk of fire. Locking Tabs Lamp Screw
Light Case Locking Tab
Note : When installing the Lamp, do not touch the surface of Lamp directly. Use a clean cloth or tissue to install the Lamp. Fig. 8