TH-37PD25U-P / TH-42PD25U-P
b. Remove coupler (CC24) connected to the C2 board. c. Remove C2 board fastening screws (�4), and remove the C2 board.
17. Remove the front frame. a. Leaving the front glass and front board unit attached to the front frame, pull the bottom of the front frame forward, lift, and remove.
15. Remove the shield plate (bottom). a. Remove the shield plate (bottom) fastening screws (�7), and remove the shield plate (bottom).
16. Remove the rear cover mounting brackets. a. Remove the rear cover mounting bracket (top) fastening screws (�4), and remove the rear cover mounting bracket (top). b. Remove the rear cover mounting bracket (left, right) fastening screws (�4 each), and remove the rear cover mounting brackets (left and right). 18. Remove stand brackets. a. Remove the plasma panel section from the servicing stand and lay on a surface such as a table (covered), with the plasma panel surface facing downward. Spread a soft cloth or similar on the table for protection, so the panel surface is not scratched. b. Remove the stand bracket (left, right) fastening screws (�4 each) and remove the stand brackets (left, right).
c. Remove the fastening screws (�2) holding the front frame and plasma panel.