|
Kto jest w sklepie?
Sklep przegląda 6028 gości
|
Kategorie
|
Informacje
|
Polecamy
|
|
|
|
|
Dla tego produktu nie napisano jeszcze recenzji!
;
Bardzo dobra jakość skanu, przystępna cena. Instrukcja serwisowa okazała się przydatna przy "reanimowaniu" dwudziestoparoletniego decka, który teraz pięknie gra :)
;
...instruction is ok.
...instrukcja jest ok.
Thanks/Dzięki
;
Documentation made available quickly and It is good quality. Thanks.
X-NM10, XR-NM1
Electrical Adjustment
Check the following before starting.
(1) Confirm that the tape speed adjustment has been completed. (2) Clean the heads and demagnetize them using a head eraser. (3) Set the measurement level to 0 dBV = 1 Vrms. (4) Use the specified tape for adjustment. Use the labeled (A) side of the test tape. NCT-132X : For playback check
Playback Adjustment
(1) Head Azimuth Adjustment
* When the tape is played with both of side panel L and R removed (state that reception front is floating from ground). when adjusting , the noise might be superimposed. In this case, the front chassis must short circuit to the CD mechanism cover in the lead wire.
Playback Adjustment
(1) Head Azimuth Adjustment
� Do not switch between forward and reverse operation with the screwdriver inserted.
Step Mode Input Signal/ Test Tape Adjusting Points Measurement Points Adjustment Value Remarks After adjustment, apply silicon bond to the head azimuth adjustment screw. SP OUT CN1 PB L ª ch Max. playback signal level PB R ªch
1
PLAY
N C T - 1 3 2 X t e s t t a p e Head azimuth adjustment (Playback: 10kHz, -20dB) screw (Fig. 4)
0 dB
30s 315 Hz
0 dB: 315 Hz, 250 nwb/m 30 s 6.3 kHz 30 s 10 kHz 30 s 315 Hz 10s .......................................................................................................... 10s �20 dB 12.5 6.3 500 250 125 14 kHz kHz 10 kHz 8 kHz kHz 4 kHz 2 kHz 1 kHz Hz Hz Hz 63 Hz 40 Hz 10s
Fig. 3 NCT-132X Test Tape
FWD Azimuth Adjustment Screw REV Azimuth Adjustment Screw
Fig. 4 Head Azimuth Adjustment
52
|
|
|
> |
|