|
Kto jest w sklepie?
Sklep przegląda 5751 gości
|
Kategorie
|
Informacje
|
Polecamy
|
|
|
|
|
Dla tego produktu nie napisano jeszcze recenzji!
USERS INSTRUCTIONS
DESCRIPTION The Royal Cozyfire is a decorative gas fire designed to fit into a conventional fire surround and fireplace. It should be fitted to a flue that conforms to a conventional Class I flue (i.e. a brick built chimney of 227 x 227mm (9x9ins) or 175mm (7ins) diameter lined or stone chimney with the fire back and fireplace components complying to BS1251. The appliance has a single aerated burner, the design of which produces a ribbon of flame that runs across the front of the fire bed. A single control with combined piezo igniter selects ignition (pilot only) and can be turned anticlockwise to select a high rate and then a reduced rate at maximum rotation. For extra safety, the tap is designed so that the gas cannot be allowed to reach the burner until the pilot is proven. A flame supervision device (FSD) is fitted to ensure that should the oxy-pilot extinguish for any reason, (including turning off the appliance) the gas supply to the burner is cut off until the full lighting sequence is repeated. The oxy-pilot or O.D.S. will cause the appliance to �shut off� in the event of continued spillage occurring under hazardous or blocked flue conditions. Various types of fire fronts and frets are recommended that can be shown by the dealer, they have perforated frets to allow air to be drawn into the coal bed for combustion and over the controls for cooling purposes. If other fronts and frets are to be used they must have a minimum open area in the fret of 20 square centimetres and 60 square centimetres in the front. See Fig 9. A decorative trim is available as an optional extra which locates on the inner edges of the fireplace/surround opening, the trim has 50mm deep flanges to assist with fixing in position. IMPORTANT NOTES The Royal Cozyfire is a decorative fuel effect appliance designed and manufactured to the requirements of the British Standards Institution BS 5258 Part 12: 1990 and EN509. It is for use on Natural Gas only. All gas appliance installations must be installed by a competent person in accordance with the current Gas Safety (Installation and Use) Regulations or the rules in force and in accordance with the attached Installation Instructions; failure to do so could lead to prosecution. The appliance is fitted with an ODS, a spillage monitoring system which operates if the evacuation of products is interrupted (i.e. blocked or incorrect flueing). If the gas fire repeatedly �goes out� it may indicate a problem and the installer or specialist should be informed before further use. The chimney flue (unless new) must be swept prior to installation. It should be checked annually for spillage (smoke test) when the appliance is serviced and that there is no excessive build up of soot. This product uses fuel effect pieces, gaskets and insulation material containing Refractory Ceramic Fibre (RCF), which are man-made vitreous silicate fibres. Excessive exposure to these materials may cause temporary irritation to eyes, skin and respiratory tract, consequently, it makes sense to take care when handling these articles to ensure that the release of dust is kept to a minimum. The appliance has a naked flame, a fireguard to British Standard BS 6539 or BS 6778 should be used for the protection of your young children, the elderly and the infirm. Combustible materials should not be put on or left in the hearth, nor should the coal bed be used to burn rubbish or other materials. Care must be taken on the selection of wall coverings within close proximity of the fire as some vinyl and embossed materials may become discoloured by convected heat. Soft furnishings must be kept clear from the radiant heat of the fire and from impinging the hearth area. The hearth must not be covered by any combustible materials such as carpet etc. The unit is secured to the hearth with two fixing screws to prevent stress on the gas inlet connection. It is recommended that the appliance is serviced annually by a competent person and the flue checked for satisfactory clearance of products and that there is no excessive build up of soot. The curing effect of heating the coals will cause an initial odour which, although not harmful, may require additional ventilation until the odour has disappeared. This appliance will run on Full for approximately 4.4 hours on one therm of gas. TO LIGHT THE APPLIANCE 1. Remove the fret (controls cover). 2. Press and turn the gas control anti-clockwise, keep the control fully depressed. The igniter will operate and the pilot will light, if not repeat the operation. 3. 0nce a pilot-flame has been established; keep the control depressed for a further 20 seconds. Release the gas control and check that the pilot remains lit.
|
|
|
> |
|