HOO 522
1. 2. 3. 4. Control panel. Grease filters. Lighting unit support (2 Lighting units). Pull-out steam deflector.
PRODUCT SHEET
To clean the grease filter
Wash the grease filter at least once a month. 1. Disconnect the electrical power supply. 2. Pull out the steam deflector. 3. Remove the grease filters: pull the side handles (c) outwards and extract the rear filter, followed by the front one. 4. After cleaning the grease filter, remount in reverse order ensuring the entire extraction surface is covered (first fit the front filter, then replace the steam deflector and finally fit the rear filter).
CONTROL PANEL
A. Speed selector switch. B. Light switch.
Replacing bulbs
1. Disconnect the electrical power supply. 2. Open the lighting unit support: push the release latches (d) of the support inwards (direction �Open� as printed on the plastic latch). 3. Remove the burnt-out bulb. Replace using 40W max (E14) bulbs only. 4. Close the lighting unit support.
small amount of steam and fumes large amount of steam and fumes medium amount of steam and fumes
Fitting or renewing the carbon filter:
Change the carbon filter at least every four months. 1. Disconnect the electrical power supply. 2. Pull out the steam deflector. 3. Remove the grease filters and open the lighting unit support. 4. If the carbon filters are already mounted and need renewing, turn the central handle (e) anticlockwise until the filters release. 5. If the carbon filters are not already fitted locate one on each side to cover both motor protection grilles, then turn the central handle (e) of the filters clockwise. 6. Refit the grease filter and close the lighting unit support.
5019 100 75202
PL CZ SK
H
RUS BG RO GB
"
|