20R-S100S
FEATURE
SERVICE POSITION M01 M02 M03 M04 M05 ADJUST ITEM MS LEVEL MTS-VCO FILTER LOW SEPARATION HIGH SEPARATION DATA
RANGE INITIAL VALUE
ADJUSTMENT CONTENTS
00-0F 00-3F 00-3F 00-3F 00-3F
0A 20 1C 20 1B
Note: Refer to the SERVICE ADJUSTMENT for each corresponding values. Table - D
Holding down both the Vol-up/Ch-down buttons on the TV set at service mode for more than 2 seconds will automatically write the above initial values into IC2102 (IC2101).
ADJUSTMENT PART REPLACED IC2001 IC201 NECESSARY UNNECESSARY NOTES Data is stored in IC2102 (IC2101). The adjustment is needed to compensate for characteristics of parts including IC201. Holding down both the Vol-up/Ch-down buttons on the TV set in the service mode for more than 2 seconds will automatically write the above initial values into IC2102 (IC2101). Adjust items related to picture tube only.