6-4. Video VCO Adjustment
1) Connect the Frequency counter to �VCO� on the VFK1308P. 2) Adjust the VCO frequency to become 41.85MHz±200KHz.
7-7. White Balance Adjustment
1) Set the Lens Cap on front of the Lens. 2) Connect the Video out to the monitor TV. 3) Compare the white level between the EVF and the Monitor TV. If there is a big difference so that white level (Phase) becomes almost same.
6-5. PG Shifter Adjustment
1) Insert the Color Bar Alignment tape (VFM3010EDS) into the Unit. 2) Adjustment is performed automatically.
6-6. RF.VITERBI Adjustment
1) Insert the self-recorded tape into the Unit. 2) Press TAB Key to start the Automatic adjustment.
7. EVF ADJUSTMENT
7-1. PLL Adjustment (Normal)
1) Connect the oscilloscope to �MON-PLL� on the VFK1308P. 2) Adjust the width (T) to become 1.8±0.1µsec as shown in figure when press the F2 Key.
7-2. PLL Adjustment (Wide)
1) Connect the oscilloscope to �MON-PLL� on the VFK1308P. 2) Adjust the width (T) to become 2.3±0.1µsec as shown in figure when press the F2 Key.
7-3. Pedestal Level Adjustment
1) Connect the oscilloscope to �MON-G� on the VFK1308P. 2) Adjust the pedestal level to become 4.1±0.1V as shown in figure when press the F2 Key.
7-4. Pedestal Level Adjustment
1) Connect the oscilloscope to �MON-G� on the VFK1308P. 2) Adjust level to become 3.4±0.1V as shown in figure when press the F2 Key.
7-5. Gamma Level Adjustment
1) Connect the oscilloscope to �MON-G� on the VFK1308P. 2) Adjust V level to become 2.1±0.1V as shown in figure when press the F2 Key.
7-6. Color Level Adjustment
1) Connect the oscilloscope to �MON-B� on the VFK1308P. 2) Adjust V level to become 0.4±0.1V as shown in figure when press the F2 Key.