In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance. INJECTORS TABLE CATEGORY II2H3+
Type of gas used NATURAL GAS (Methane) G 20 LIQUID PETROLEUM GAS (Cylinder) G 30 LIQUID PETROLEUM GAS (Cylinder) G 31 Type of burner large medium large medium large medium Injector marking 128 94 85 65 85 65 Rated heat capacity Pcs-kW 3.00 1.65 3.00 1.65 3.00 1.65 Reduced Rated heat consumption capacity Pcs-kW 286 l/h 157 l/h 218 g/h 120 g/h 214 g/h 118 g/h 0.60 0.35 0.60 0.35 0.60 0.35 Gas pressure min. 17 rat. 20 max. 25