|
Kto jest w sklepie?
Sklep przegląda 4539 gości
|
Kategorie
|
Informacje
|
Polecamy
|
|
|
|
|
Dla tego produktu nie napisano jeszcze recenzji!
;
Wszystko w porządku.
Instrukcja czytelna i kompletna.
Dziękuję.
all right!
thank you.
;
Bardzo dobra instrukcja. Zawiera wszystko co potrzeba, polecam!
;
Instrukcja jest OK. Schematy czytelne, opisane niektóre procedury.
;
Instrukcja bardzo czytelna. zawiera co potrzeba. Polecam
;
...instrukcja serwisowa w pełni czytelna i kompletna. Dziękuję!
AL-1250
3. AE level adjustment (OC mode)
[Input method] When the PHOTO lamp lights up, press and hold the density select key for 5 sec, and the AUTO mode lamp will blink and the adjusted level will be displayed on the exposure level display. [Adjustment] For adjustment, press the density adjustment key too select the density in 5 steps. [Terminating method] Press the density select key, and the model display will turn from blinking to lighting to terminate the AE level adjustment.
4. AE level adjustment (SPF mode)
[Input method] While the SPF mode lamp is lighting, when the PHOTO mode lamp lights up, press and hold the density select key for 5 sec, and the AUTO mode lamp will blink and the adjusted level will be displayed on the exposure level display. [Adjustment] For adjustment, press the density adjustment key to select the density in 5 steps. [Terminating method] When the density select key is pressed, the mode display will turn from blinking to lighting to terminate the AE level adjustment.
5. Toner save mode setup and cancel
[Input method] When the TEST mode lamp lights up, press and hold the density select key for 5 sec, and the PHOTO mode lamp will turn from blinking to lighting and the adjusted level will be displayed on the exposure level display. [Setup/Cancel] Press the left key: Level �1� ON, toner save mode setup Press the right key: Level �5� ON, toner save mode cancel. [Terminating method] When the density select key is pressed, the mode display turns from blinking to lighting to terminate setup.
8-2
|
|
|
> |
|