Troubleshooting
Note � Do not close the front cover removing the photoconductor unit. Otherwise, you cannot replace the photoconductor unit because the photoconductor unit holder will be closed. If you do this by mistake, return the
I Hold the inset grips (green part)
of the new photoconductor unit, and push the photoconductor unit to its original position.
J Fix the photoconductor unit with
fastening the screws using the screw driver.
photoconductor unit holder to its original position before replacing the photoconductor unit.
K Close the front cover.
Make sure that the front cover close properly.
L Turn
on the printer�s power switch.
TFWX300E
Replacing the Fuser Oil Bottle and Ozone Filter
Replace the oil bottle and ozone filter whenever the message shown below appears on the panel display.
6
H Hold the inset grips (green part)
of the new photoconductor unit, and insert the photoconductor unit into the photoconductor unit holder. When inserting the photoconductor unit, be careful not to damage the surface of it.
IPDL-C Add FuserOil Add FuserOil
There is the fuser oil bottle and the ozone filter in the Fuser Oil Type305.
R WARNING: � Do not incinerate the oil bottle.
TFWX305E
Note � The white powder on the photoconductor unit is to protect it after installation into the printer. This white powder does not have any adverse effect on the interior of the printer.
This action could cause a fire or getting burned. � Spilt oil is very slippery. If oil is spilt, wipe it with alkaline cleaner. Otherwise, the oily surfaces can create the danger of slipping and personal injury.