...instrukcja serwisowa w pełni czytelna i kompletna. Dziękuję!
Tekstowy podgląd strony 56 (kliknij aby zobaczyć)
AV-48WP74 AV-56WP74 Measuring instrument Signal generator Remote control unit
Item A-D CONVERTER OFFSET adjustment (2)
Test point
Adjustment part [1.PICTURE/SOUND] F44 : Image adjustment F45 : Image adjustment of mode change F47 : Minimum value B at the time of detection F48 : Maximum value A at the time of detection [8.PP] ADM012 : R offset AMD013 : G offset AMD014 : B offset
Description [WHITE BALANCE LOW LIGHT ADJUSTMENT for SPLIT RIGHT SCREEN] (1) Press [SPLIT] key to enter the SPLIT screen mode. (2) Select STANDARD with [VIDEO STATUS] key. (3) Select FULL mode with [ASPECT] key. (4) Select 1 PICTURE SOUND from SERVICE MENU. (5) It goes into the zero mode screen of difference adjustment of color, using <F45>(Image adjustment mode change) as 0 to 3 and <F44>(Image adjustment) as 0 to 1. (6) Set <F47> (minimum value B at the time of detection) to 0 and <F48> (minimum value A at the time of detection) to 0. (7) Press [MUTING] key and memorize the set value. (8) Press [BACK] key and back to SERVICE MENU. (9) Select 8.PP from SERVICE MENU. (10) Adjust <ADM012> (R offset setup) and <ADM014> (G offset setup) so that right upside screen becomes whole black. (11) Press [MUTING] key and memorize the set value. (12) Select 1.PICTURE/SOUND from SERVICE MENU. (13) Change the data of <F44> 1 to 0 and <F45> 3 to 0. (14) Press [MUTING] key and memorize the set value.