Documentation made available quickly and It is good quality. Thanks.
Tekstowy podgląd strony 13 (kliknij aby zobaczyć)
2-8. R Signal De-matrix Adjustment 2-9. G Signal De-matrix Adjustment
2-8. R Signal De-matrix Adjustment
Measurement equipment Waveform monitor Procedure 1. Check to see that S505 is set to RGB. 2. Supply 100% color bars signal from the signal generator to the SDI IN connector. 3. Set the waveform monitor as follows. MODE : WAVEFORM INPUT : CH3 REF : EXT 4. Adjust 1RV305 so that the level A satisfies the specification. Use 1RV303 in the fine adjustment so that the peak of each level is flat. n Do not set S505 to YUV until �2-9. G Signal Dematrix Adjustment� is completed. Measuring point : R-Y/R connector (BKPF-102CB connector panel) Adjustment point : 1RV303 (F-6)/DAC-30 (for fine adjustment) 1RV305 (H-6)/DAC-30
2-9. G Signal De-matrix Adjustment
n Adjust the G signal after the B signal (section 2-7) and R signal (section 2-8) adjustments are completed. Measurement equipment Waveform monitor Procedure 1. Check to see that S505 is set to RGB. 2. Supply 100% color bars signal from the signal generator to the SDI IN connector. 3. Set the waveform monitor as follows. MODE : WAVEFORM INPUT : CH1 REF : EXT 4. Adjust 1RV404 so that the level A satisfies the specification. 5. Set S505 to YUV. Measuring point : Y/G connector (BKPF-102CB connector panel) Adjustment point : 1RV404 (H-5)/DAC-30