1-1-4.
Adjustment remote commander (RM-95 upgraded) To perform adjustment, the adjustment data stored in the non-volatile memory must be rewritten using the adjustment remote commander (RM-95 upgraded). The adjustment remote commander uses the remote commander signal line (LANC) to interactively communicate with the merchandise. The page, address and up/down command data are sent from the adjustment remote commander to the merchandise. In return, the page, address and data are sent to the adjustment remote commander from the merchandise. 1. Using the adjustment remote commander 1) Connect the adjustment remote commander to the LANC 2) terminal (CF-44 board J000). Set the NOR-ADJ (or HOLD) switch of the adjustment remote commander to the �ADJ� (or ON) (service) position. If the adjustment remote commander is correctly connected, the adjustment remote commander�s LED will show the display as shown in Fig. 6-1-6. Bit value discrimination It is necessary to discriminate between the bit values with the data displayed on the adjustment remote commander for all following items. Identify whether the bit value is �1� or �0� with the use of the following diagram. A
Display on the adjustment remote commander 0 1 2 3 4 5 6 7 8 9 A (A) B (b) C (C) D (d) E (E) F (F) bit3 or bit7 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
(Example) If �8E� is displayed on the adjustment remote commander, the bit values for bit7 to bit4 are shown in the �A� column, and the bit values for bit3 to bit0 are shown in the �B� column.