SECTION 4 ELECTRICAL BLOCK CHECKING
Note :
1. CD Block is basically designed to operate without adjustment. Therefore, check each item in order given. 2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated. 3. Use an oscilloscope with more than 10M impedance. 4. Clean the object lens using an applicator with neutral detergent when the signal level is low than specified value with the following checks. S Curve Check
oscilloscope BD board TP (FE) TP (VC)
Note: Clear RF signal waveform means that the shape � � can be clearly distinguished at the center of the waveform.
RF signal waveform VOLT/DIV : 200mV TIME/DIV : 500ns level : 1.2 +0.25 Vp-p
�0.20
Procedure : 1. Connect oscilloscope to test point TP (FE) on BD board. 2. Connect between test point TP (FEI) and TP (VC) by lead wire. 3. Turn Power switch on. 4. Put disc (YEDS-18) in and turn Power switch on again and actuate the focus search. (actuate the focus search when disc table is moving in and out.) 5. Check if the oscilloscope waveform (S-curve) is symmetrical between A and B. And confirm peak to peak level within 3±1 Vpp.
S-curve waveform symmetry
Procedure : 1. Connect test point TP1 (ADJ) to ground with a lead wire on MAIN board. 2. Connect oscilloscpe to test point TP (TE) on BD board. 3. Turned Power switch on. 4. Put disc (YEDS-18) in to play the number five track. 5. Press the �3� button. (The tracking servo and the sledding servo are turned OFF.) 6. Check the level B of the oscilliscope's waveform and the A (DC voltage) of the center of the Traverse waveform. Confirm the following : A/B x 100 = less than ± 22%
A within 3 ± 1 Vp-p B
Traverse waveform Center of the waveform B 0V A (DC voltage)
6. After check, remove the lead wire connected in step 2. Note : � Try to measure several times to make sure than the ratio of A : B or B : A is more than 10 : 7. � Take sweep time as long as possible and light up the brightness to obtain best waveform. RF Level Check
level : 1.3 ± 0.6 Vp-p
7. Press the �8� button. (The tracking servo and sledding servo are turned ON.) Confirm the C (DC voltage) is almost equal to the A (DC voltage) is step 6.
oscilloscope Traverse waveform
BD board TP (RF) TP (VC)
Procedure : 1. 2. 3. 4. Connect oscilloscope to test point TP (RF) on BD board. Turned Power switch on. Put disc (YEDS-18) in to play the number five track. Confirm that oscilloscope waveform is clear and check if RF signal level is correct or not.
0V Tracking servo Sledding servo OFF Tracking servo Sledding servo ON
C (DC voltage)
8. Disconnect the lead wire of TP (ADJ) connected in step 1.