CT-34WX53
Place the light reception food of the white balance meter on center of Low (Black) parts in picture pattern. (See Fig. 2) 10. Adjust data of �CUT R� and �CUT B� so that white balance meter may indicate following value. If luminance is different from following value, Readjust data of �BRT�.
9.
(FIG. 2) Food position of white balance meter
[NTSC LOW LIGHT] *Set the food of White balance meter to position that Color SAG is nothing.
HIGH LIGHT ADJUSTMENT
11. Place the light reception food of the White balance meter on position that the food bottom edge is 2~3cm UP from V-center of High (White) parts in picture pattern. (See Fig. 3) 12. Adjust data of �R DR� and �B DR� so that White balance meter may indicate following value. If luminance is different from following value, Readjust data of �CONT�.
[NTSC HIGH LIGHT]
(Fig. 3) Food position of White balance meter 2~3cm
13. Confirm the White balances of Low light. If it is poor, Repeat item 12 to item 16. 14. If you change data of �CONT�, Return former data.
HD WHITE BALANCE
15. 16. 17. 18.
Set COLOR TEMP to COOL. Apply HD White balance pattern. Confirm that HD White balance is as same as NTSC . If adjust level is no good, re-adjust white balance for HD.