PRODUCT SPECIFICATIONS AIR CONDITIONER OPERATION
ECONOMY OPERATION
ECONOMY
°F hr
CHECK TIMER SETTING DURING OFF TIMER
°F
ECONOMY
To reduce power consumption: � Press ECONOMY. � To cancel this operation, press once more.
TIMER
hr
°F hr
Press the TIMER button to check the remaining programmed timer setting. The figure will be displayed for 10 seconds then will automatically switch back to temperature setting. NOTE The timer figure will change according to the time remaining (if you set it to turn off 3 hours from now, the timer will show �2� at an hour later).
ECONOMY Recommended for electricity cost saving. When economy button is pressed, target temperature is shifted up 1°F, this will reduce operating time of the compressor and therefore reduce power consumption. It may, however, take a little longer for the compressor to cycle on and thereby increase the room temperature slightly. Economy mode will override your current set fan speed to �LOW�. However, the display will still show the current set fan speed. Compressor stops when the room temperature reaches the target temperature. It turns on again when the room temperature rises. When power failure occurs, the economy setting is canceled. Once power is resumed, reset the economy setting.
TIMER
CANCEL TIMER SETTING DURING OFF TIMER
SET
°F hr
SET/ CANCEL
SET/ CANCEL
Press the SET/CANCEL button to cancel the timer setting. The SET/ CANCEL indicator light will turn off. However the temperature remains displayed.
SETTING THE OFF TIMER
TIMER
°F hr
TEMP/TIMER
°F hr
SET
SET/ CANCEL
°F hr
When the air conditioner in operation: Press the TIMER button. The SET/CANCEL indicator light will blink awaiting for setting. Press the TEMP/TIMER v or w button until the preferred hour of operation is reached. Press the SET/CANCEL button to complete the setting. At this time, the SET/CANCEL indicator light is steady instead of blinking. NOTE The hour reading will change back to the set temperature reading after 10 seconds. (You can also revert to temperature setting immediately by pressing the TEMP/TIMER v or w buttons again.)
TIMER
TEMP/TIMER
SET/ CANCEL
6
Model COOLING CAPACITY ELECTRICAL RATING Phase Frequency Voltage Current Input Btu/h (Hz) (V) (Amps) (W) (Btu/W.h) (Pints/h) (Cf/min) Height Width Depth cm (inches) cm (inches) cm (inches) kg (lb) kg (lb) Indoor (Hi/Lo) Outdoor (Hi/Lo) dB (A) dB (A)
CW-XC122VU 11,500 Single 60 115 10.1 1150 10.0 3.0 330 37.5 (14-25/32�) 56 (22-1/16�) 60.6 (23-27/32�) 35 (77) 39 (86) 51/47 58/55
EER MOISTURE REMOVAL ROOM AIR CIRCULATION DIMENSIONS
NET WEIGHT GROSS WEIGHT NOISE LEVEL
* Specifications are subject to change without notice for further improvement.
|
|
|
> |
|