...instrukcja serwisowa w pełni czytelna i kompletna. Dziękuję!
Tekstowy podgląd strony 246 (kliknij aby zobaczyć)
FIXING UNIT
a. (1) (2) (3) (4)
Caution: This is an important safety part. (P/N: SP00-0020) Be sure to observe the following cautions and steps when removing or reinstalling. Caution1: After reinstalling the thermostat/U, make sure that its wires do not touch the fixing upper roller. Caution2: When reinstalling the thermostat/U, adjust its position using the positioning jig (4024-2152-01) and secure it with screws. Be sure to apply screw lock agent to the screws. This adjustment should be made in a pressured state. Removal procedure Remove the fixing unit. Remove the web cover. Remove the cleaning web. Remove one screw and two Faston terminals to detach the thermostat/U. Thermostat/U (TS1) Screw
f) Set the distance "a" between the thermostat/ U and fixing upper roller so that it is equal to the thickness (B) of the positioning jig. Thermostat/U (TS1) Faston terminals (2)
b
Fixing upper roller Standard value of b : 3.75 ± 0.1 mm
1-O-11
1 3 DIS./ASSEMBLY
[13] Removing and Reinstalling the Thermostat/U (TS1)
b. Reinstallation procedure (1) Connect two Faston terminals to the thermostat/ U. (2) Set a thermostat positioning jig (4024-2152-01) between the thermostat/U and fixing upper roller and secure the thermostat/U with one screw so that the distance between the roller and thermostat/U is equal to the thickness of the jig.