2-13.BARRIER UNIT
5 Ornamental fixed plate (A) 1 Switch on a power supply. 2 Push zoom button and transform the lens as shown below. 3 Switch off a power supply by taking out a battery or cut off a power supply from AC daptor. (without using camera�s power swich) 6 Two screws (M1.4 � 4.5) 7 Barrier unit
A
4 Pinch A portion with finger and fit a driver over a hollow.
[BARRIER OPERATION TEST METHOD]
After the barrier unit is replaced, check the following items with turning the power of the set ON/OFF. � The lens moves out and the barrier shutters open completely when the power is turned on. � The lens moves in and the barrier shutters close completely when the power is turned off. Checking condition is 1 downward 2 45° downward 3 horizontal 4 45° upward 5 upward; totally five positions and check three times for each position.
1 downward
2 45° downward
3 horizontal
4 45° upward
5 upward
The test needs to be performed only when the barrier unit is replaced. No performance of this test is needed when the lens is replaced.