ALIGNMENT INSTRUCTIONS
7. GEOMETRY
7-1. VERTICAL CENTER ADJUSTMENT
1) Receive the RETM A PATTERN signal. 2) Set the user control A UTO PIC TURE to STANDARD m ode. 3) Press S6 button on the SVC rem ote control to display M ENU 4) Press CH buttons on the S VC rem ote control to select V CENTER and press VOL buttons on the SVC rem ote control to adjust the horizontal line of RETM A PATTERNS center m ay m eet with the m echanical CE NTER of C RT. 5) Press the RECA LL button on the SVC rem ote control to store.
7-2. VERTICAL SIZE ADJUSTMENT
1) Receive the RETM A PATTERN signal. 2) Set the user control AUTO PICTURE to STANDA RD m ode. 3) Press S 6 button on the SVC rem ote control to display M ENU 4) Press buttons on the SVC rem ote control to select V SIZE and press V OL buttons to adjust the CENTER OF C IRCU M FEREN CE of big circle m ay m eet with the upper and Lower sides of screen. 5) Press the RE CALL button on the S VC rem ote control to store.
CH
7-3. VERTICAL LINEARITY ADJUSTMENT
1) R eceive the RETM A PATTERN signal. 2) S et the user control AU TO PIC TURE to STANDARD m ode. 3) P ress S6 button on the SVC rem ote control to display M ENU 4) P ress
CH buttons on the SV C rem ote control to select V LIN,VS CO R 5) A djust VOL buttons to be round center circle of RETM A PATTERN
6) P ress the RECA LL button on the SVC rem ote control to store.
7-4. HORIZONTAL CENTER ADJUSTMENT
1) Receive the RETM A PATTERN signal. 2) Set the user control AUTO PICTURE to S TANDAR D m ode. 3) Press S6 button on the SVC rem ote control to display M ENU 4) Press buttons on the SVC rem ote control to select H CEN TER and press VO L buttons on the SVC rem ote control to adjust the left and right W ID TH of RETM A PATTERN becom e sym m etrical. 5) Press the REC ALL button on the SVC rem ote control to store.
CH
7-5. HORIZONTAL WIDTH ADJUSTMENT
1) Receive the RE TM A PATTERN signal. 2) Set the user control AUTO PICTURE to STAN DARD m ode. 3) Adjust R406 in order to set the left and right end of RETM A PATTERN on point 5.