jedyne do czego mogę mieć zastrzeżenie to jakość zdjęć zawartych w przesłanej instrukcji serwisowej ponieważ są fatalnej jakości, praktycznie nieczytelne. tak poza tym jestem zadowolony to jest to czego szukałem.
Instrukcja jest OK. Schematy czytelne, opisane niektóre procedury.
Tekstowy podgląd strony 14 (kliknij aby zobaczyć)
ALIGNMENT INSTRUCTIONS
7. GEOMETRY
7-1. VERTICAL CENTER ADJUSTMENT
1) Receive the RETM A PATTERN signal. 2) Set the user control A UTO PIC TURE to STANDARD m ode. 3) Press S6 button on the SVC rem ote control to display M ENU 4) Press CH buttons on the S VC rem ote control to select V CENTER and press VOL buttons on the SVC rem ote control to adjust the horizontal line of RETM A PATTERNS center m ay m eet with the m echanical CE NTER of C RT. 5) Press the RECA LL button on the SVC rem ote control to store.
7-2. VERTICAL SIZE ADJUSTMENT
1) Receive the RETM A PATTERN signal. 2) Set the user control AUTO PICTURE to STANDA RD m ode. 3) Press S 6 button on the SVC rem ote control to display M ENU 4) Press buttons on the SVC rem ote control to select V SIZE and press V OL buttons to adjust the CENTER OF C IRCU M FEREN CE of big circle m ay m eet with the upper and Lower sides of screen. 5) Press the RE CALL button on the S VC rem ote control to store.
CH
7-3. VERTICAL LINEARITY ADJUSTMENT
1) R eceive the RETM A PATTERN signal. 2) S et the user control AU TO PIC TURE to STANDARD m ode. 3) P ress S6 button on the SVC rem ote control to display M ENU 4) P ress
CH buttons on the SV C rem ote control to select V LIN,VS CO R 5) A djust VOL buttons to be round center circle of RETM A PATTERN
6) P ress the RECA LL button on the SVC rem ote control to store.
7-4. HORIZONTAL CENTER ADJUSTMENT
1) Receive the RETM A PATTERN signal. 2) Set the user control AUTO PICTURE to S TANDAR D m ode. 3) Press S6 button on the SVC rem ote control to display M ENU 4) Press buttons on the SVC rem ote control to select H CEN TER and press VO L buttons on the SVC rem ote control to adjust the left and right W ID TH of RETM A PATTERN becom e sym m etrical. 5) Press the REC ALL button on the SVC rem ote control to store.
CH
7-5. HORIZONTAL WIDTH ADJUSTMENT
1) Receive the RE TM A PATTERN signal. 2) Set the user control AUTO PICTURE to STAN DARD m ode. 3) Adjust R406 in order to set the left and right end of RETM A PATTERN on point 5.