Documentation made available quickly and It is good quality. Thanks.
Tekstowy podgląd strony 46 (kliknij aby zobaczyć)
DV-K102
7.1.2 TROUBLE SHOOTING
� No Power ON � FL is not turned ON � FL indication is unusual
START � Blow out fuse of the primary side � Blow out micro-fuse on the POWER SUPPLY Assy. (Check the each voltage.) (P611, P211, P711) � FL controller IC (IC101) on the FLKY Assy is damaged.
Power ON
Turn on the power again after 2 - 3 minutes. � Check the following connections : POWER SUPPLY Assy - DVDM Assy DVDM Assy - FLKY Assy FLKY Assy - PWSB Assy � Check each voltage (EV+5V, SW+5V, SW+3.3V, +6V and +12V) (If above voltage are not supplied, check the micro-fuse.)
Is FL turn on ? Yes
No
Is the indication of FL normal ? Yes
No
FL indication is dark or flickers.
� Short or open the zenner diode on the POWER SUPPLY Assy. (D513) � Check the values of R110 - R120 on the FLKY Assy.
Indicates the error message
Refer to the section "7.1.3 ERROR CODE".
� Blow out micro-fuse on the POWER SUPPLY Assy. (P711)
Is tray open ? Yes
No