DVR-S201
SERVO MECHANISM ASSY and PICKUP ASSY 2 1
Floating Base
�4 �2
Connecting the Flexible Pickup Cable
Caution: Be sure to turn the LD short switch to the Short (lower) side when you remove the flexible pickup cable.
� Side view LD short SW Open
3
Short Remove the Pickup Flexible Cable and a connector, then remove the Servo Mechanism Assy.
Note: Turn the Short SW of the Pickup Assy to Short side (lower side).
1. Insert the FPC with the conductor side upward. Properly insert it to the slot until it stops. 2. Push down both sides of the lock lever until they stop. It cannot be locked with one side only. Imperfection of pushing down may cause unlocking.
FP
Pickup Assy Guide Shaft
C re
tac cep
les
2
FPC conductor side
2
1
Disconnecting the flexible pickup cable
1. Pull up the lock lever upward. 2. After unlocking, pull out the FPC.