Gruba instrukcja - poprostu wszystko co potrzreba - polecam .
Tekstowy podgląd strony 7 (kliknij aby zobaczyć)
Adaptation to different types of gas
FInjectors replacement
Remove the pan supports. Remove the burner's caps and crowns. With a socket spanner 7 unscrew and remove the injectors (Fig. 7), and replace them with the ones required for the type of gas in use (see table 2). � Reassemble the parts, following the same procedure backwards. � Replace the rating label (placed near the gas supply pipe) with the relevant one for the new type of gas supply. You can find this label in the package of the injectors supplied with the appliance. Should the feeding gas pressure be different or variable compared with the required pressure, an appropriate pressure adjuster must be fitted on the gas supply pipe, in compliance with the rules in force. � � �
Fig. 7
FO 0392
FAdjustment of minimum
To adjust the minimum level of the burners, proceed as follows:
level
Fig. 8
� � � �
Light the burner. Turn the knob on the minimum position. Remove the knob. With a thin screwdriver, adjust the by-pass screw (see Fig. 8). If changing from natural gas to LPG, completely tighten clockwise the screw, until a small regular flame is obtained. If changing from LPG to natural gas unscrew about 1/4 turn the by-pass screw, until a small regular flame is obtained.
By-pass screw
Table 1 : By-pass diameters
Burner � By-pass in 1/100 of mm. 28 32 40
� Finally check the flame does not go out when quickly
turning the knob from the maximum position to the minimum position. This procedure can easily be carried out, anyhow the hob has been positioned or built in the working top.
Auxiliary Semi-rapid Rapid
Table 2 : injectors
TYPE OF GAS TYPE OF BURNER INJECTORS MARKS 1/100 mm NOMINAL POWER INPUT KW 3,0 2,0 1,0 2,8 2,0 1,0 REDUCED POWER kW NOMINAL POWER 3 m /h 0,286 0,190 0,095 g/h 202 144 72 NOMINAL PRESSURE mbar