Electrical connection
The appliance is arranged to operate on a 230 V singlephase power supply. Connection must be made in compliance with current standards and regulations. Before carrying out the connection, make sure: 1) the limiter valve and the electrical system can take the appliance load (refer to the serial no. plate); 2) the supply system is equipped with an efficient earth connection in compliance with current standards; 3) the socket or omnipolar switch used are easily accessible with the appliance installed. Fit the cable with a plug suitable for the load and connect it to a suitable safety socket. To connect directly to the mains, a suitable omnipolar switch with contact gap of at least 3 mm complying with current standards must be installed between the appliance and the network. The yellow/green earth wire must not be interrupted by the switch. The brown phase wire (coming from terminal �L� on the terminal block) must always be connected to the power supply phase wire. In any case the power cable must be positioned in such a way that no part of it reaches a temperature of more than 90°C. An example of an optimum path is given in Fig. 8. The cable is guided by means of clamps fixed to the side of the cabinet, in order to avoid any contact with the equipment beneath the cooktop.
REPLACING THE POWER CABLE When replacing the power cable only use H05V2V2-F T90 type cables suitable for the load and operating temperature. Also, the yellow/green earth wire must be approx. 2 cm longer than the phase and neutral wires (Fig. 9). After connection, test the heating elements by operating them for about 3 minutes.