Gruba instrukcja - poprostu wszystko co potrzreba - polecam .
Tekstowy podgląd strony 19 (kliknij aby zobaczyć)
Minimum level adjustment of gas oven burner
This procedure must be undertaken by a competent and qualified engineer only. 1. Disconnect the appliance from the mains supply. 2. Remove all the knobs. 3. Open the oven door and locate the ventilation grill which is fixed right below the control panel. 4. Remove the rubber caps from the ventilation grill then undo the two fixing screws (�A�) and finally take the grid off. Undo the two fixing screws (�B�) which keep the control panel in place, then take it off the appliance. With a thin bladed screwdriver, completely tighten the minimum level adjustment screw (�C�). Refit all the oven parts following the above described procedure backwards. Restore the mains supply. Do not restore the mains supply if all the removed parts have not been fitted back in their original position.
A
5.
6. 7. 8.
9. Light the oven gas burner (see the relevant chapter), set the gas oven control knob on 240 and let the oven heat for 10 minutes at least. 10.Check that the oven gas burner flame does not fail when quickly turning the gas oven control knob from 240 to 150. 11.Should the oven gas burner flame fail when performing point 10, repeat the whole procedure from point 1 to point 10, until a small regular flame is obtained on the complete gas oven burner crown.