a) It is accompanied by the registration section cut out of the booklet, together with the original purchase receipt, which will be returned with the replacement part. b) A competent person has carried out any installation, repairs or adjustments, such as the supplier�s representative or a CORGI registered installer. Maintenance and Servicing GENERAL A. REMOVAL OF DEBRIS OR SOOT DEPOSITS Allow the appliance to cool sufficiently before removing all of the coals and firebed components for cleaning purposes. Once all the ceramics are removed from the firebed check that no debris is located in the burner slots (both front and rear). If any debris is present it may easily be removed by using a small piece of cardboard to ease out any foreign matter. Be sure to remove the cardboard after use. Any sooty deposits or debris left on the coals may be removed by using a soft brush. To
ensure that the release of fibres from these RCF articles is kept to a minimum, during installation and servicing we recommend that you use a HEPA filtered vacuum to remove any dust and soot accumulated in and around the fire before and after working on the fire. When replacing these articles we recommend that the replaced items are not broken up, but are sealed within heavy duty polythene bags, clearly labelled as RCF waste. This is not classified as "hazardous waste" and may be disposed of at a tipping site licensed for the disposal of industrial waste. Protective clothing is not required when handling these articles, but we recommend you follow the normal hygiene rules of not smoking, eating or drinking in the work area and always wash your hands before eating or drinking. Sooty
deposit on the thermocouple probe can be cleaned oft using a non-fluffy cloth. DO NOT USE ABRASIVE MATERIALS B. SERVICING COMPONENTS BELOW THE BURNER ASSEMBLY Turn OFF the gas supply to the appliance. Remove coals, coal supports, side cheeks, burner inserts and front simulated coal. To gain access to components below the burner assembly it has to be removed from the convector box by disconnecting the gas supply at the inlet elbow and unscrewing the two screws at the base of the facia panel. Where the supply is fed from the right hand side across the front of the fire it will be necessary to disconnect the supply from the isolation tap/elbow. TO CLEAN OR REPLACE THE INJECTOR: Unscrew the compression nut connecting the gas supply to the elbow injector while supporting the injector to prevent distortion of the framework. Unscrew and remove the gas supply tube from the gas control valve, hold the injector lock nut with a spanner and rotate the injector. Replace in reverse order. TO REPLACE THE GAS CONTROL (Tap/FSD): Disconnect the three gas pipes and the thermocouple from the control. Pull off the knob and lay to one side. Undo the retaining nut at the front of the tap niting assembly to withdraw control from the mounting bracket. Replace in reverse order. TO REPLACE THE PIEZO IGNITER: Pull off the HT lead from the rear of the igniter, prevent the metal fixing nut from turning, rotate the body of the igniter to unscrew and withdraw the igniter from the front. Replace in reverse order and reconnect the HT lead. TO REPLACE THE OXY-PILOT ASSEMBLY: The operation of the oxy-pilot depends on the proximity of the spark electrode and the thermocouple tip. If either of these components are defective the assembly must be replaced by removing the tube nut and tube from the base of the pilot and the thermocouple from the FSD also the igniter lead and the two M4 screws securing the bracket to the framework. Replace in reverse order, the spark gap is shown opposite.
- 12 Short Parts List
|
|
|
> |
|