|
Kto jest w sklepie?
Sklep przegląda 5046 gości
|
Kategorie
|
Informacje
|
Polecamy
|
|
|
|
|
Dla tego produktu nie napisano jeszcze recenzji!
BEFORE CALLING FOR SERVICE
The following conditions do not denote equipment malfunctions UNIT DOES NOT OPERATE
The unit will not operate if it is turned on immediately after it is turned off. The unit will not operate immediately after the mode is changed. This is to protect the internal mechanisms. Wait 3 minutes before operating the unit.
SWISHING NOISE
The soft, swishing noise is the sound of the refrigerant flowing inside the unit.
WATER VAPOUR
� In the COOL and DRY operation, water vapour can sometimes be seen at the air outlet due to the difference between the room air temperature and the air discharged by the unit. � In the HEAT operation, water vapour may flow out of the outdoor unit during de-icing.
UNIT DOES NOT SEND OUT WARM AIR
The unit is preheating or de-icing.
ODORS
Carpet and furniture odors that entered into the unit and the air conditioner's inner component odors at the early stage of installation may be sent out from the unit.
THE OUTDOOR UNIT DOES NOT STOP
After stopping the operation, the outdoor unit will rotate its fan for about a minute to cool down the unit.
CRACKING NOISE
The unit may produce a cracking noise. This sound is generated by the friction of the front panel and other components expanding or connecting due to a temperature change.
ODOR EMITTED FROM THE PLASMACLUSTER AIR OUTLET
This is the smell of ozone generated from the Plasmacluster ion generator. Density of the ozone is very little, having no adverse effect over your health. The ozone released into the air will decompose soon, and its density in the room will not increase.
A LOW BUZZ NOISE EMITTED
This is a sound emitted when the unit is generating Plasmacluster ions.
If the unit appears to be malfunctioning, check the following points before calling for service.
IF THE UNIT FAILS TO OPERATE
Check to see if the circuit breaker has tripped or the fuse has blown.
IF THE UNIT FAILS TO COOL (OR HEAT) THE ROOM EFFECTIVELY
Check the filters. If dirty, clean them. Make sure windows and doors are closed tightly. Check the outdoor unit to make sure nothing is blocking the air inlet or outlet. A large number of people in the room can prevent the unit from achieving the desired temperature. Check the thermostat is proper setting. Check whether any heat-generating appliances are operating in the room.
IF THE UNIT FAILS TO RECEIVE THE REMOTE CONTROL SIGNAL
Check whether the remote control batteries have become old and weak. Try to send the signal again with the remote control pointed properly towards the unit�s signal receiver window. Check whether the remote control batteries are installed with the polarities properly aligned.
Please call for service when OPERATION Lamp and TIMER Lamp on the indicator panel blink.
E-18
|
|
|
> |
|