Kto jest w sklepie?
Sklep przegląda 6043 gości
|
Kategorie
|
Informacje
|
Polecamy
|
|
|
|
|
- SERVICING NOTES
- GENERAL
- Location of Controls
- Setting the Time
- DISASSEMBLY
- TEST MODE
- MECHANICAL ADJUSTMENTS
- ELECTRICAL ADJUSTMENTS
- DIAGRAMS
- Block Diagram - CD SERVO Section
- Block Diagram - TAPE DECK Section
- Block Diagram - MAIN Section
- Block Diagram - DISPLAY/KEY CONTROL/POWER SUPPLY Section
- Note for Printed Wiring Boards and Schematic Diagrams
- Printed Wiring Board - BD Board
- Schematic Diagram - BD Board
- Printed Wiring Boards - CD MOTOR Section
- Schematic Diagram - CD MOTOR Section
- Printed Wiring Board - AUDIO Board
- Schematic Diagram - AUDIO Board
- Printed Wiring Board - LEAF SW Board
- Schematic Diagram - LEAF SW Board
- Printed Wiring Board - MAIN Board
- Schematic Diagram - MAIN Board (1/4)
- Schematic Diagram - MAIN Board (2/4)
- Schematic Diagram - MAIN Board (3/4)
- Schematic Diagram - MAIN Board (4/4)
- Printed Wiring Board - PANEL Board
- Schematic Diagram - PANEL Board
- Printed Wiring Board - CD SW Board
- Schematic Diagram - CD SW Board
- Printed Wiring Board - TRANSFORMER Section
- Schematic Diagram - TRANSFORMER Section
- IC Pin Function Description
- EXPLODED VIEWS
- ELECTRICAL PARTS LIST
Dla tego produktu nie napisano jeszcze recenzji!
;
Schematy są ale można wysilić się i zrobić kolorowy skan i o większej rozdzielczości. Wtedy schematy płytek będą czytelniejsze. Całość super jako wartość merytoryczna. Wszystkie dane potrzebne do podłączenia różnego rodzajów urządzeń takich gramofon, CD itd.
;
Szybko, sprawnie i tanio. Serwis godny polecenia. Będę polecał innym
;
Ogólnie jest OK, z wyjątkiem obrazu płyty głównej, który jest miejscami mało czytelny, ale można sobie poradzić.
;
Dokładna dokumentacja, pomogła w szybkiej naprawie telewizora. Dziękuję!
;
jedyne do czego mogę mieć zastrzeżenie to jakość zdjęć zawartych w przesłanej instrukcji serwisowej ponieważ są fatalnej jakości, praktycznie nieczytelne. tak poza tym jestem zadowolony to jest to czego szukałem.
CD SECTION
Note: 1. CD Block is basically designed to operate without adjustment. Therefore, check each item in order given. 2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated. 3. Use an oscilloscope with more than 10 M� impedance. 4. Clean the object lens by an applicator with neutral detergent when the signal level is low than specified value with the following checks.
E-F Balance (1 Track Jump) Check
oscilloscope BD board TP (TE) TP (VC)
+ �
S-Curve Check
oscilloscope BD board TP (FE) TP (VC)
+ �
Procedure : 1. Connect oscilloscpe to TP (TE) and TP (VC). 2. Turn the power ON. 3. Load a disc (YEDS-18) and playback the number five track. 4. Press the ^ (CD) button. (Becomes the 1 track jump mode) 5. Confirm that the level B and A (DC voltage) on the oscilloscope waveform.
1 track jump waveform
Procedure: 1. Connect oscilloscope to TP (FE). 2. 3. 4. 5. Connect between TP (FE1) and TP (VC) by lead wire. Connect between TP (AGCCON) and TP (GND) by lead wire. Turn the power ON. Load a disc (YEDS-18) and actuate the focus search. (In consequence of open and close the disc tray, actuate the focus search) 6. Cofirm that the oscilloscope waveform (S-curve) is symmetrical between A and B. And confirm peak to peak level within 4 ± 1 Vp-p.
S-curve waveform
symmetry
center of waveform B 0V A (DC voltage)
level = 1.3 ± 0.6 Vp-p
symmetry
A Specified level: B � 100 = less than ± 22%
6. After check, remove the lead wire connected in step 1.
A within 4 ± 1 Vp-p B
7. After check, remove the lead wire connected in step 2 and 3.
Note: � Try to measure several times to make sure than the ratio of A : B or B : A is more than 10 : 7. � Take sweep time as long as possible and light up the brightness to obtain best waveform.
RF Level Check
oscilloscope BD board TP (RF) TP (VC) + �
Procedure: 1. Connect oscilloscope to TP (RF). 2. Connect between TP (AGCCON) and TP (GND) by lead wire. 3. Turn the power ON. 4. Load a disc (YEDS-18) and playback. 5. Confirm that the oscilloscope waveform is clear and check RF signal level is correct or not. 6. After check, remove the lead wire connected in step 2.
Note: Clear RF signal waveform means that the shape ��� can be clearly distinguished at the center of the waveform.
VOLT/DIV: 200 mV TIME/DIV: 500 ns
level: 1.45 ± 0.3 Vp-p
� 17 �
|
|
|
> |
|