jedyne do czego mogę mieć zastrzeżenie to jakość zdjęć zawartych w przesłanej instrukcji serwisowej ponieważ są fatalnej jakości, praktycznie nieczytelne. tak poza tym jestem zadowolony to jest to czego szukałem.
Instrukcja bardzo czytelna. zawiera co potrzeba. Polecam
Tekstowy podgląd strony 21 (kliknij aby zobaczyć)
HCD-RG66T
CD SECTION
Note: 1. CD Block is basically designed to operate without adjustment. Therefore, check each item in order given. 2. Use LUV-P01 (4-999-032-01) unless otherwise indicated. 3. Use an oscilloscope with more than 10M� impedance. 4. Clean the object lens by an applicator with neutral detergent when the signal level is low than specified value with the following checks.
Note: Clear RF signal waveform means that the shape � � � can be clearly distinguished at the center of the waveform.
RF signal waveform VOLT/DIV : 200mV TIME/DIV : 500ns
Procedure : 1. Connect an oscilloscope to TP (FEO). 2. Connect between TP (FEI) and TP (DVC) ( 1.65 V) by lead wire. 3. Turn the power ON. 4. Load a disc (LUV-P01) and actuate the focus search. (In consequence of open and close the disc tray, actuate the focus search) 5. Confirm that the oscilloscope waveform (S-curve) is symmetrical between A and B. And confirm peak to peak level within 2 ± 0.5 Vp-p.
S-curve waveform symmetry
Procedure : 1. Connect an oscilloscope to TP (TEO) and TP (DVC). 2. Turn the power ON. 3. Load a disc (LUV-P01) and playback the number nine track. 4. Press the hH button. (Becomes the 1 track jump mode.) 5. Confirm that the level B and A (DC voltage) on the oscilloscope waveform.
1 track jump waveform center of waveform B
A within 2 ±0.5Vp-p B
DVC level=1.0 ±0.5Vp-p symmetry
A (DC voltage)
6. After check, remove the lead wire connected in step 2.
Note: � Try to measure several times to make sure than the ratio of A : B or B : A is more than 10 : 7. � Take sweep time as long as possible and light up the brightness to obtain best waveform.
6. Adjust RV101 on the BD board so that the center of waveform becomes the same voltage of DVC. (i.e. A=0V) Connecting and Adjustment Location: BD board
Procedure : 1. Connect an oscilloscope CH1 to TP (RFDC) and CH2 to TP (RFAC). 2. Turn the power ON. 3. Load a disc (LUV-P01) and playback. 4. Confirm that oscilloscope waveform is clear and check if RF signal level is correct or not.