Instructions for Installation (cont'd)
Locating Heater the New Water
AWARNING
This water heater must not be installed directly on carpeting. Carpeting must be protected by a metal or wood panel beneath the appliance extending beyond the full width and depth of the appliance by at least 3 inches (76.2mm) in any direction, or if the appliance is installed in an alcove or closet, the entire floor must be covered by the panel. Failure to heed this warning may result in a fire hazard. You should carefully" choose an indoor location for the new water heater, because the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not for usein manufactured (mobile) homes or outdoor installation, Whether replacing an old water heater or putting the water heater in a new location, the following critical points must be observed. The location selected should be indoors as close as practical to the gas vent or chimney to which the water heater vent is going to be connected, and as centralized with the water piping system as possible. The water heater, as all water heaters, will eventually leak. Do not install without adequate drainage provisions where water flow w_Ucausedamage,
a_, WARNING Minimum clearances between combustible construction arethe water heater and i 1" at the sides rear, 4" at the front, and 6" from the vent pipe. Clearance from the top of the jacket is 18" on most models. Note that a lesser dimension may be allowed on some models. Refer to the label on the[ water heater adjacent to the gas control valve for all clearances.
A CAUTION [ WATER HEATERS EVENTUALLY LEAK: Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak, the flow of water will not cause damage to the structure. For this reason, it is not advisable to install the water heater in an attic or upper floor. When such locations cannot be avoided, a suitable drain pan should be installed under the water heater. Drain pans are available at your local hardware store. Such a drain pan must be not greater than 1½ inches deep, have a minimum length and width of at least 2 inches greater than the water heater dimensions and must be piped to an adequate drain. The pan must not restrict combustion air flow. Under no circumstances is the manufacturer or Maytag to be held liable for any water damage in connection with this water heater.
,2"HAX
_1"
_I"HIN.
--
_ VENTILATION OPENINGSO A,R ,
oTOF_Ios_ " W--I_,HIN WITHOUT DOOR T_V_ SET _'.AX. WITHDOOR
OFDOOR
FRONTVIEW
KECTANGULAP, 3"
JJ
I AI_DUCT HIN.
IJ
j Figure 1 I I I
/dEDUCT
_WARNING
A gas water heater cannot operate properly without the correct amount of air for combustion. Do not install in a confined area such a closet, unless
AWARNING
Propellants of aerosol sprays and volatile cornpounds, (cleaners, chlorine based chemicals, refrig- I erants, etc.) in addition to being highly flammable I in many cases, will also change to corrosive[ hydrochloric acid when exposed to the combustion products of the water heater. The results can be hazardous, and also cause product failure.
Water Heater" as shown in the "Locating flow of you provide air section. Never obstruct the The New ventilation air. If you have any doubts or questions at all, call your gas company. Failure to provide the proper amount of combustion air can result in a fire or explosion and can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.
The location selection must provide adequate clearances for servicing and proper operation of the water heater.