Gruba instrukcja - poprostu wszystko co potrzreba - polecam .
Tekstowy podgląd strony 11 (kliknij aby zobaczyć)
KV-32S42/32S66/32V42/35S42/35S66/35V42
2-5-1. PICTURE TUBE REMOVAL
WARNING: BEFORE REMOVING THE ANODE CAP High voltage remains in the CRT even after the power is disconnected. To avoid electric shock, discharge CRT before attempting to remove the anode cap. Short between anode and CRT coated earth ground strap.
(KV-32S42/32V42/32S66)
Coated Earth Ground Strap
2-5-2. PICTURE TUBE REMOVAL
WARNING: BEFORE REMOVING THE ANODE CAP High voltage remains in the CRT even after the power is disconnected. To avoid electric shock, discharge CRT before attempting to remove the anode cap. Short between anode and CRT coated earth ground strap.