(2) If LED terminals are not seen from the back of Front Panel Assy After the LED was replaced, adjust the brightness with the Unit Alignment Controller. (Refer to service manual JME-US30L)
2 Louver Note: When mounting the Louver, pass all LEDs through the holes in the Louver. Cutter Pliers 6 Pull off the LED. <Caution on mounting LED> . Do not confuse the polarity. . Mount the LED in the midway, apply RTV, then push it in completely. Note: When mounting the C board, apply RTV to the periphery of C board as a measure of waterproofing.
3 Cut off the periphery of C board with a cutter.
4 C board 5 Remove the solder and stretch leads straight.
1 Nine screws (+B3 x 8) Torque force to tighten the screws: 0.8 N.m ± 0.1
Note: Take away the urethane foam inside of the panel when cutting off the C board. Caution for Static Electricity to LED Cell The LED is very weak to static electricity, and a discharge of static electricity could shorten the LED life. Wear the earth bands when touching the LED or the connector of the LED cell to replace the LED cell or handle the unit.