|
Kto jest w sklepie?
Sklep przegląda 6043 gości
|
Kategorie
|
Informacje
|
Polecamy
|
|
|
|
|
Dla tego produktu nie napisano jeszcze recenzji!
;
...instruction is ok.
...instrukcja jest ok.
Thanks/Dzięki
;
Documentation made available quickly and It is good quality. Thanks.
MC-GG773-00
3.5.
3.5.1.
Power Cord Replacement
Removal
3.6.
3.6.1.
Switch ON-OFF Replacement
Removal
1. Remove the switch cover and dust cover to expose the electrical connections of the power cord.
1. Remove the switch cover expose the electrical connections of the switch.
2. Unplug the lead wire terminals from switch. 3. Pull out the switch from switch cover. 2. Remove the strain relief (for power cord replacement) and cut the wire connections. 3. Pull the power cord out of the dust compartment (for power cord replacement).
3.6.2.
Installation
1. Insert the new switch into the switch cover. Connect the two lead wires on the new switch. 2. Replace the switch cover, and the four (4) switch cover screws. Care should be taken not to pinch wires and make sure that the switch cover goes on easily and stays flat. If there is resistance to the switch cover lying flat and in place, stop, remove the cover and make sure that no wires are being pinched. DO NOT USE A POWER SCREWDRIVER TO SECURE THE COVER. NOTE: For general servicing, it is necessary to eliminate pinching of any wire during reassembly. After servicing any electrical component or electrical enclosure, the unit should be reassembled and checked for dielectric breakdown or current leakage.
3.5.2.
Installation
1. Insert the new power cord (power cord replacement only) into the dust compartment as far as necessary in order to place a new cord retainer in proper location on power cord. The proper location is approximately one and one eighth inches / thirty millimeters (1 1/8� / 30 mm) of new power cord outer jacket extending past the strain relief. Attach wires with wire connectors according to the wiring diagram in the front of this manual. ONLY USE A NEW STRAIN RELIEF, DO NOT REUSE A STRAIN RELIEF. 2. Replace the switch cover, the four (4) switch cover screws, and the dust cover. Care should be taken not to pinch wires and make sure that the switch cover goes on easily and stays flat. If there is resistance to the switch cover lying flat and in place, stop, remove the cover and make sure that no wires are being pinched. DO NOT USE A POWER SCREWDRIVER TO SECURE THE COVER. NOTE: For general servicing, it is necessary to eliminate pinching of any wire during reassembly. After servicing any electrical component or electrical enclosure, the unit should be reassembled and checked for dielectric breakdown or current leakage.
3.7.
3.7.1.
Handle Release Assembly
Removal
1. Turn the vacuum over and remove the lower plate, belt and agitator as outlined in their respective removal sections. 2. Remove the switch cover and dust cover to freely lift the nozzle housing and slide it out from the motor shaft.
3. Remove the three (3) screws that secure the handle release 13
|
|
|
> |
|