[Configuration of Test Mode] [Test Mode $Display Check Mode%] Press the > or [VOL +] key [Manual Mode] Press the x key [Servo Mode] [Audio Mode] [Power Mode] [OP Alignment Mode]
Press the . or [VOL --] key
[VOL +] key:100th place of mode number [Major item switching]
N key x key
increase. [VOL --] key:100th place of mode number decrease.
[VOL +] key:10th place of mode number [Medium item switching] increase. [VOL --] key:10th place of mode number
N key x key
decrease.
[Overall Adjustment Mode]
Press the x key Press the N or [REC] key on the set Press the x key
[Minor item switching]
N key: Unit place of mode number
increase.
[Adjusted value variation] [VOL +] key:Increases the
adjusted value [VOL --] key:Decreases the adjusted value
[Sound Skip Check Result Display Mode]
Move up the jog key on the set or [DISPLAY] key press the on the remote commander Press the x key Press the [T MARK] or [DISPLAY] key on the remote commander for several seconds.
[Self-Diagnosis Display Mode]
[Adjusted value write]
X key: When adjusted value is
[Key Check Mode]
Quit the key check or open the upper panel
changed: Adjusted value is written. When adjusted value is not changed: That item is adjusted automatically.
[Manual Mode]
Mode to adjust or check the operation of the set by function. Normally, the adjustment in this mode is not executed. � Transition method in Manual Mode 1. Setting the test mode. (See page 11) 2. Press the > or [VOL +] key activates the manual mode where the LCD display as shown below.
LCD display
000
Manual
3. The optical pick-up moves outward or inward while the > or . key is pressed for several seconds respectively. 4. Each test item is assigned with a 3-digit mode number; 100th place is a major item, 10th place is a medium item, and unit place is a minor item.