Documentation made available quickly and It is good quality. Thanks.
Tekstowy podgląd strony 69 (kliknij aby zobaczyć)
IV.
EXPOSURE
SYSTEM
2. Removing
the Thermal
Fuse
A. SCANNER 1. Removing the Scanning Lamp
1) Unplug the copier. 2) Remove the control panel and copyboard glass. 3) Unscrew the two screws and remove the reflector.
1) Remove the control panel and copy. board glass. 2) Grasp the rear of mirror 1 mount move it to the right, and bring it to the part shown in Figure 4-44. Note: Be sure to hold the rear of the mirror mount at the rear when moving it. 3) Unscrew the two mounting screws, then remove the thermal fuse. 1
4) Push the contact (rear) in the direction of the arrow and remove the scanning lamp.
@ Lamp contact
0
Scanning lamp
Figure 4-43 Note: 1. The scanning lamp will be hot, if it has been operating recently. 2. Never touch the surface of the scanning lamp, with bare hands. 3. If the scanning lamp is dirty, wipe it with a dry cloth. If there are any fingerprints or skin oil on it, clean them off with solvent.