English 16. Altering the operating voltage and frequency (Reserved for technical staff only)
If the operating voltage and frequency as preset by coemar does not correspond to that of the country in which you are operating, you may alter the preset by following the instructions in the paragraphs which follow. An error in voltage or frequency selection may seriously compromise the correct functioning of the projector.
16.1 Selecting the voltage on the autotransformer
1) Remove the screws on the base of the fixture, as shown in the picture below, then simply lift the covers to access the internal components of the ProWash 575 LX.
2) Locate the autotransformer. 3) Select the tension among 115, 208, 230 and 240V disconnetting cable n° 22 and moving it on the desired tension. For a correct selection, refer to the label on the autotransformer. Cables n° 4,23, 24 e 25 should not be moved from their position for any reason. 4) If the tension you chose is 115V replace the 8 Amps T fuse ,ideal for a selection at 208/230/245 V, with a 15 Amps T one. the fuse holder is located on the base of the fixture. You will find the replacement fuse in a plastic bag attached to this present manual
T8A @230V T15A @115V
5) Proceed now to select the frequency as described in the next paragraph, or replace the covers and close the base. 6) Cross on the label located on the baseof the ProWash 575 LX the tension you just selected, as shown in the picture on the following page