Instrukcja Serwisowa jest kompletna i czytelna. Dziękuję!
Tekstowy podgląd strony 14 (kliknij aby zobaczyć)
PT-P1SDU / PT-P1SDE / PT-P1SDEA
(with J-P.C.Board).
Note: · When installing the lamp unit (or a new one) in the main unit, place it in a specified position and press the connector side and the opposite side of the lamp unit (arrow positions shown in the figure below), and confirm the lamp unit is inserted securely. Then, tighten the 1 screw fixing the lamp unit, and attach the lamp unit cover.
6. Unscrew the 3 screws and remove the analysis block, LCD block and lens.
7. Unscrew the 4 screws A and remove the lens. 8. Unscrew the 2 screws B and remove the LCD block (the analysis block remains).
6.11. Removal of Analysis Block and Lens
1. Remove the lamp unit according to the section 6.10. "Removal of Lamp Unit". 2. Remove the upper case according to the section 6.2. "Removal of Upper Case". 3. Unscrew the 2 screws and remove the light shield metal. 4. Unscrew the 1 screw and remove the grounding metal 2.
6.12. Removal of LCD Block
1. Remove the A-P.C.Board according to the section 6.3. "Removal of A-P.C.Board". 2. Unscrew the 2 screws and remove the LCD block. Note: · Be careful not to touch the surface of prism and LCD panel. 5. Unscrew the 2 screws and remove the A-P.C.Board block