GB Your fridge-freezer needs air
The refrigerating unit does not require any maintenance. All it needs is proper ventilation. Air intake takes place through the base of the upright kitchen unit. Provision for air outlet must be made at the top behind the upright kitchen unit. In such a unit, a clear air inlet and outlet cross-section of at least 200 cm2 must be provided in the base and towards the room ceiling. Ensure that these openings are not obstructed by base panels, etc.! 1. The wire which is coloured green and yellow must be connected to the earth terminal in your plug, which is marked with the letter E or by the earth symbol or coloured green, or green and yellow. 2. The wire which is coloured brown must be connected to the live terminal which is marked with the letter L or coloured red. 3. The wire which is coloured blue must be connected to the neutral terminal which is marked with the letter N or coloured black. When wiring the plug, ensure that all strands of wire are securely retained in each terminal. Do not forget to tighten the mains lead clamp on the plug. Warning! A cut-off plug inserted into a 13 amp socket is a serious safety (shock) hazard. Ensure that the cut-off plug is disposed of safely. Voltage 220/240 V AC Fuse rating 13 amps See rating plate for further information. The rating plate is inside, on the left.
Before using for the �rst time
In common with all new appliances, your fridgefreezer will smell "new". For this reason, the interior of the fridge-freezer and all accessories should be cleaned before use (see also "Cleaning and care").
Electrical connection
WARNING - THIS APPLIANCE MUST BE EARTHED Please ensure that the voltage and current indicated on the rating plate agree with the voltage of your electricity supply. 220/240 volts (i. e. 220/240 V AC). If your appliance has been equipped with a mains lead with a moulded-on type plug, you must comply with the following regulations: The plug moulded on to the cord incorporates a fuse. For replacement, use a 13 amp BS 1362 fuse. Only ASTA approved or certi�ed fuses should be used. The fuse cover/ carrier must be replaced in the event of changing the fuse. The plug must not be used if the fuse cover/ carrier is lost. A replacement cover/carrier must be obtained from an electrical goods retailer. If the socket outlets in your home are not suitable for the plug �tted to the appliance, then the plug must be cut off and an appropriate one �tted. When �tting the plug please note the following points: Important The wires in the mains lead are coloured in accordance with the following code: Green and Yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:
Preparing the upright kitchen unit
Fig. 2 Before installing the upright furniture unit, the back panel must be removed where �tted as a transport safety device. To ensure satisfactory operation and sealing of the appliance, the upright kitchen unit with its intermediate panels must be exactly at right-angles in all directions and must be aligned vertically. The doors of the upright kitchen unit should be aligned before the appliance is installed, and the hinge screws should be tightened. The distance between the kitchen unit door and unit sides should be 1 mm.
Rehingeing the door
Figs. 3, 4, and 5 During transport, the doors are secured with bolts. Unscrew the LH upper and lower bolts with a screw-driver (Fig. 3) . Both doors can now be opened to the right. If the doors are to be opened to the left to ensure better operation, you should also unscrew the bolts on the RH side and unhinge the upper door upwards.