Insulating tube Warning label F-temp. control knob
70_2mm +
R-Cbox cover D timer lead ass�y
Fig. A-17 1. Connect D timer lead ass'y to Defrost timer, R thermostat. 2. Screw Lamp to Lamp socket. (Fig. A-18)
D timer lead ass�y
4 3 2 1
5. Fix R thermostat with screw and make up the tube of R thermostat as shown Fig. A-20.
Screw R thermostat Paper taping 40 X 80
Defrost timer
Lamp R thermostat Lamp socket
Insulating tube
Fig. A-18 3. Fix Lamp socket with screw, and Defrost timer with screw. 4. Cover the capillary tube of R thermostat by Insulating tube and bend them as shown in FigA-19.
25mm
9±2
100 + 5mm
Fig. A-20 6. Insert F-temp. control knob to R thermostat. 7. Stick warning label on R-cbox cover as shown Fig. A-21.
R-Cbox cover 50±2
Insulating tube A R thermostat
80mm 25_2mm + 15_2mm + 55_2mm + 55mm 185mm
+5 5 -0mm
View From A
Warning label
Fig. A-19 NOTE Minimum bending radius is R5. There should be no gas leakage by reforming of Capillary tube. 19 Fig. A-21 8. Set R-air guider ass'y on R-cbox cover.